Home/Product/siemens simatic pcs 7
Product

siemens simatic pcs 7

48 known vulnerabilities across versions
Vulnerabilities are listed by affected version. Select any CVE for the full briefing and its intelligence graph.
CVE-2023-48364
<= 9.1
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2
6.5MEDIUM
CVE-2023-48363
<= 9.1
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2
6.5MEDIUM
CVE-2023-28829
all versions
A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIM
3.9LOW
CVE-2023-25910
all versions
A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1),
10.0CRITICAL
CVE-2022-24287
<= 9.0
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMAT
7.8HIGH
CVE-2021-40363
<= 8.2
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (A
7.8HIGH
CVE-2021-40360
<= 8.2
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (A
8.8HIGH
CVE-2021-40364
<= 8.2
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMAT
5.5MEDIUM
CVE-2021-40359
<= 8.2
A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (A
7.7HIGH
CVE-2021-40358
all versions
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMAT
9.9CRITICAL
CVE-2020-10048
all versions
A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure p
5.5MEDIUM
CVE-2020-7586
all versions
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3)
7.8HIGH
CVE-2020-7585
all versions
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3)
7.8HIGH
CVE-2020-7580
all versions
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions
6.7MEDIUM
CVE-2019-19282
all versions
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions
7.5HIGH
CVE-2019-10935
all versions
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with
7.2HIGH
CVE-2019-10922
<= 8.0
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions),
9.8CRITICAL
CVE-2019-10918
<= 8.0
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with
8.8HIGH
CVE-2019-10917
<= 8.0
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with
5.5MEDIUM
CVE-2019-10916
<= 8.0
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with
8.8HIGH
CVE-2018-4832
<= 7.1
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (A
7.5HIGH
CVE-2017-14023
all versions
An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2
4.9MEDIUM
CVE-2017-12069
<= 8.1
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS)
8.2HIGH
CVE-2016-9160
<= 8.0
A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < SIMATIC PCS
8.1HIGH
CVE-2016-7165
<= 7.1
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versio
6.4MEDIUM
CVE-2014-8552
all versions
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through
CVE-2014-8551
all versions
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through
CVE-2014-4686
<= 8.0
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded en
CVE-2014-4685
<= 8.0
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak sys
CVE-2014-4684
<= 8.0
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to
CVE-2014-4683
<= 8.0
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users
CVE-2014-4682
<= 8.0
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain
CVE-2013-3959
<= 8.0
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits d
CVE-2013-3958
<= 8.0
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier an
CVE-2013-3957
<= 8.0
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7
CVE-2013-0679
<= 8.0
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other
CVE-2013-0678
<= 8.0
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator cred
CVE-2013-0677
<= 8.0
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to
CVE-2013-0676
<= 8.0
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the d
CVE-2013-0675
<= 8.0
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 befor
CVE-2013-0674
<= 8.0
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other pro
CVE-2012-3034
all versions
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover
CVE-2012-3032
all versions
SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allo
CVE-2012-3031
all versions
Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7
CVE-2012-3030
all versions
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under
CVE-2012-3028
all versions
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and
CVE-2012-3015
<= 7.1
Untrusted search path vulnerability in Siemens SIMATIC STEP7 before 5.5 SP1, as used in SIMATIC PCS7 7.1 SP3 and earlier and other
CVE-2010-2772
all versions
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database an
7.8HIGH
Vulnerabilities
CISA KEV catalog
CWE weaknesses
CAPEC attack patterns
Package vulnerabilities
Threat intelligence
Threat actors
Tools & malware
ATT&CK techniques
IOCs
Detection & defense
Sigma rules
YARA rules
Atomic Red Team tests
D3FEND countermeasures
Compliance
NIST 800-53
ISO 27001:2022
SOC 2 TSC
PCI-DSS v4.0
CIS Controls v8.1