Home/Product/flir ax8 firmware
Product

flir ax8 firmware

14 known vulnerabilities across versions
Vulnerabilities are listed by affected version. Select any CVE for the full briefing and its intelligence graph.
CVE-2018-25139
all versions
FLIR AX8 Thermal Camera 1.32.16 contains an unauthenticated vulnerability that allows remote attackers to access live video stream
7.5HIGH
CVE-2018-25138
all versions
FLIR AX8 Thermal Camera 1.32.16 contains hard-coded SSH and web panel credentials that cannot be changed through normal camera ope
9.8CRITICAL
CVE-2025-6266
< 1.49.16
A vulnerability was detected in Teledyne FLIR AX8 up to 1.46. Affected by this vulnerability is an unknown functionality of the fi
6.3MEDIUM
CVE-2025-5695
>= 1.46.0 and <= 1.46.16
A vulnerability has been found in Teledyne FLIR AX8 up to 1.46.16. This impacts the function subscribe_to_spot/subscribe_to_delta/
4.7MEDIUM
CVE-2025-5127
>= 1.46.0 and <= 1.46.16
A vulnerability was determined in Teledyne FLIR AX8 up to 1.46.16. This issue affects some unknown processing of the file /prod.ph
3.5LOW
CVE-2025-5126
>= 1.46.0 and <= 1.46.16
A vulnerability was found in Teledyne FLIR AX8 up to 1.46.16. This vulnerability affects the function setDataTime of the file \usr
8.8HIGH
CVE-2024-3013
>= 1.46.0 and <= 1.46.16
A flaw has been found in Teledyne FLIR AX8 up to 1.46.16. The impacted element is an unknown function of the file /tools/test_logi
6.3MEDIUM
CVE-2023-51127
all versions
FLIR AX8 thermal sensor cameras up to and including 1.46.16 are vulnerable to Directory Traversal due to improper access restricti
7.5HIGH
CVE-2023-51126
<= 1.46.16
Command injection vulnerability in /usr/www/res.php in FLIR AX8 up to 1.46.16 allows attackers to run arbitrary commands via the v
9.8CRITICAL
CVE-2022-4364
>= 1.46.0 and < 1.46.16
A vulnerability has been found in Teledyne FLIR AX8 up to 1.46.16. Affected by this issue is some unknown functionality of the fil
7.3HIGH
CVE-2022-37063
<= 1.46.16
All FLIR AX8 thermal sensor cameras versions up to and including 1.46.16 are vulnerable to Cross Site Scripting (XSS) due to impro
5.4MEDIUM
CVE-2022-37062
<= 1.46.16
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are affected by an insecure design vulnerability due to an
7.5HIGH
CVE-2022-37061
<= 1.46.16
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are vulnerable to Remote Command Injection. This can be ex
9.8CRITICAL
CVE-2022-37060
<= 1.46.16
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access
7.5HIGH