threat
engine
.sh
Back
·
··:··
Home
/
Product
/
rockwellautomation factorytalk linx
Product
rockwellautomation factorytalk linx
14 known vulnerabilities across versions
Vulnerabilities are listed by affected version. Select any CVE for the full briefing and its intelligence graph.
Sort
Newest first
Oldest first
Highest CVSS
Lowest CVSS
Min CVSS
Any
4.0+
7.0+ (High)
9.0+ (Critical)
Published since
Reset
CVE-2025-9068
< 6.50
A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, ins
7.8
HIGH
CVE-2025-9067
< 6.50
A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid W
7.8
HIGH
CVE-2025-7972
< 6.50
A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, t
9.1
CRITICAL
CVE-2023-29464
all versions
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via c
8.2
HIGH
CVE-2020-5806
<= 6.11
An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStr
5.5
MEDIUM
CVE-2020-5802
<= 6.11
An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted
7.5
HIGH
CVE-2020-5801
<= 6.11
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in
7.5
HIGH
CVE-2020-27255
<= 6.11
A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unau
7.5
HIGH
CVE-2020-27253
<= 6.11
A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a re
7.5
HIGH
CVE-2020-27251
<= 6.11
A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unau
9.8
CRITICAL
CVE-2020-12005
all versions
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and p
7.5
HIGH
CVE-2020-12003
all versions
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and p
7.5
HIGH
CVE-2020-12001
all versions
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and p
9.8
CRITICAL
CVE-2020-11999
all versions
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and p
8.1
HIGH
Vulnerabilities
CISA KEV catalog
CWE weaknesses
CAPEC attack patterns
Package vulnerabilities
Threat intelligence
Threat actors
Tools & malware
ATT&CK techniques
IOCs
Detection & defense
Sigma rules
YARA rules
Atomic Red Team tests
D3FEND countermeasures
Compliance
NIST 800-53
ISO 27001:2022
SOC 2 TSC
PCI-DSS v4.0
CIS Controls v8.1
About
All capabilities
Live statistics
Data sources
Privacy policy
Terms of service
threatengine.sh · Open-source threat intelligence platform · 100+ authoritative sources · Every fact traces to its origin