Home/Product/schneider electric evlink smart wallbox evb1a firmware
Product

schneider electric evlink smart wallbox evb1a firmware

18 known vulnerabilities across versions
Vulnerabilities are listed by affected version. Select any CVE for the full briefing and its intelligence graph.
CVE-2021-22822
< 3.4.0.2
A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could
6.1MEDIUM
CVE-2021-22821
< 3.4.0.2
A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to u
8.6HIGH
CVE-2021-22820
< 3.4.0.2
A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access ove
9.8CRITICAL
CVE-2021-22819
< 3.4.0.2
A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of
4.3MEDIUM
CVE-2021-22818
< 3.4.0.2
A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unau
7.5HIGH
CVE-2021-22774
< r8_v3.4.0.1
A CWE-759: Use of a One-Way Hash without a Salt vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8
7.5HIGH
CVE-2021-22773
< r8_v3.4.0.1
A CWE-620: Unverified Password Change vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1)
6.5MEDIUM
CVE-2021-22730
< r8_v3.4.0.1
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0
9.8CRITICAL
CVE-2021-22729
< r8_v3.4.0.1
A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1)
9.8CRITICAL
CVE-2021-22728
< r8_v3.4.0.1
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVli
6.5MEDIUM
CVE-2021-22727
< r8_v3.4.0.1
A CWE-331: Insufficient Entropy vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVli
9.8CRITICAL
CVE-2021-22726
< r8_v3.4.0.1
A CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V
8.1HIGH
CVE-2021-22723
< r8_v3.4.0.1
A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CS
6.1MEDIUM
CVE-2021-22722
< r8_v3.4.0.1
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Stored Cross-site Scripting') vulnerability exists in EVli
5.4MEDIUM
CVE-2021-22721
< r8_v3.4.0.1
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVli
5.3MEDIUM
CVE-2021-22708
< r8_v3.4.0.1
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions
7.2HIGH
CVE-2021-22707
< r8_v3.4.0.1
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0
9.8CRITICAL
CVE-2021-22706
< r8_v3.4.0.1
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City
6.1MEDIUM