CVE-2023-6409
< 16.0
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to a project file protected with
7.7HIGH
CVE-2023-6408
< 16.0
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could
8.1HIGH
CVE-2023-27975
< 16.0
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in Eco
7.1HIGH
CVE-2023-27976
>= 15.1
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visi
8.8HIGH
CVE-2023-1548
>= 15.1
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through
5.5MEDIUM
CVE-2022-45789
all versions
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus function
8.1HIGH
CVE-2022-45788
all versions
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, de
7.5HIGH
CVE-2022-37302
< 15.1
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash o
5.5MEDIUM
CVE-2022-37300
< 15.1
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in re
9.8CRITICAL
CVE-2022-26507
< 15.1
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to
9.8CRITICAL
CVE-2021-22797
< 15.1
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause mali
7.8HIGH
CVE-2022-24323
< 15.0
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communicatio
5.3MEDIUM
CVE-2022-24322
< 15.0
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disrupt
5.3MEDIUM
CVE-2021-22782
< 15.0
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, includin
5.5MEDIUM
CVE-2021-22781
< 15.0
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, includin
5.5MEDIUM
CVE-2021-22780
< 15.0
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, includin
7.1HIGH
CVE-2021-22779
< 15.0
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including a
9.1CRITICAL
CVE-2021-22778
< 15.0
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, includin
7.1HIGH
CVE-2020-7560
all versions
A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former n
8.6HIGH
CVE-2020-7559
all versions
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStru
7.5HIGH
CVE-2020-7538
all versions
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Exp
7.5HIGH
CVE-2020-28213
all versions
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Uni
8.8HIGH
CVE-2020-28212
all versions
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Contro
9.8CRITICAL
CVE-2020-28211
all versions
A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all vers
7.8HIGH
CVE-2020-7475
<= 14.0
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vuln
9.8CRITICAL
CVE-2019-6855
< 14.1
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all ve
7.3HIGH
Vulnerabilities
CISA KEV catalog
CWE weaknesses
CAPEC attack patterns
Package vulnerabilities
Threat intelligence
Threat actors
Tools & malware
ATT&CK techniques
IOCs
Detection & defense
Sigma rules
YARA rules
Atomic Red Team tests
D3FEND countermeasures
Compliance
NIST 800-53
ISO 27001:2022
SOC 2 TSC
PCI-DSS v4.0
CIS Controls v8.1
About
All capabilities
Live statistics
Data sources
Privacy policy
Terms of service
threatengine.sh  ·  Open-source threat intelligence platform  ·  100+ authoritative sources  ·  Every fact traces to its origin